Wastewater Analysis for Chemical Parameters

  • Analytical devices for municipal sewage plant monitoring
  • Technology for legal limit testing in industrial process effluents
  • Measuring instruments for monitoring landfill leachates

Download e-book

 

We help you to generate fast measurement results in accordance with environmental legislation. Increase the efficiency of your lab work even with wastewater samples containing high particle content.

Increase your analysis quality

  • Excellent particle handling (TOC and AOX)
  • Special hard- and software for turbid samples (UV/Vis)
  • Correct quantification of elements with high matrix tolerance

 

Accelerate your process

  • Ready for use equipment (TOC and AOX)
  • Fast instrument setup changes to fulfill different application needs
  • Highest degree of sampling automation
  • Direct safety monitoring (Self Check System)
  • High matrix tolerance faciliates analysis of challenging samples
  • Comprehensive service and support

 

Analyze with our products

  • Total organic carbon and total bound nitrogen TOC analysis
  • Adsorbable organic halogens, total halogens, and extractable organic halogens AOX analysis
  • Toxic elements, e.g., chromium, cadmium, mercury, lead AAS, ICP-OES, ICP-MS
  • SAC value, turbidity, ammonium, phosphate, nitrate, and chemical oxigen demand UV/Vis spectroscopy

 

Our analysis technologies for municipal wastewater, industrial effluents, or landfill leachates significantly reduce the effort needed for sample preparation and particle handling, while shortening measuring times for complex samples. With compliant measuring methods and robust analytical equipment, we help you to adhere to legal standards.

What our customers say

Reliable device and quickly available, competent suppor

"We appreciate Analytik Jena as a reliable partner in the field of AOX and TOC/TNb analysis. The devices work very reliably in routine operation. In the rare case of software and hardware problems, the support staff are always available  at short notice and have already provided us with very good telephone support on several occasions. Our contacts at Analytik Jena are also happy to help with challenging matrices and the adaptation of methods. In addition, the service team is also available at short notice to solve problems. Spare parts and consumables are quickly available if required."

Dr Michael Schell, Head of Wastewater Division, Limbach Analytics, Germany 

Exclusive e-book: Water and wastewater analysis

Our exclusive e-book offers a comprehensive overview of methods and solutions for water and wasterwater monitoring - from UV/Vis spectroscopy, sum parameter analysis to elemental analysis and microbiological testing.

DOWNLOAD NOW

Web Seminar: Comprehensive Sewage Sludge Analysis

This webinar describes specific sample preparation and analytical methods for sewage sludge. For elemental analysis including phosphorus, solutions based on the techniques ICP-OES, ICP-MS and AAS will be presented. For the determination of chlorine and fluorine contents, the parameters of adsorbable (AOX) or extractable organic halogen compounds (EOX) and extractable organic fluorine compounds (EOF) are presented.

watch now

Sum parameter analysis TOC, TN, and AOX in wastewater

The sum parameters total organic carbon (TOC) and total bound nitrogen (TNb) have to be measured routinely at the influent and effluent of a sewage treatment plant, both to operate the plant in the best possible manner and to meet legal limits. A sub-fraction of TOC belongs to a more toxic and persistent substance class of the halogenated hydrocarbons, which can be determined by the sum parameter AOX (adsorbable organically bound
halogens).

Web Seminar: Monitoring PFAS and Other Organically Bound Halogens in Water and Wastewater

This web seminar is intended for lab managers and analytical chemists looking for solutions to the challenges posed by AOX and PFAS monitoring in wastewater, surface water, and other water matrices.

WATCH NOW

Web Seminar: TOC/TNb and AOX in wastewater

Wastewater analysis often involves samples with high particulate content and difficult matrices, requiring complex sample preparation, pretesting and robust analytical methods. Find out how to generate fast and reliable measurement results in accordance with environmental regulations. Make lab work more efficient despite the complexity of analytical tasks in relation to wastewater samples with high particle load.

WATCH NOW

EU wastewater monitoring – TOC a key parameter

As a result of the implementation of the EU Industrial Emissions Directive (IED), the TOC parameter, in particular, is being introduced broadly into the monitoring of wastewater in various industries. Read this article to learn which industries are affected and how you can prepare for the new requirements.

Read the article

Applications sum parameter analysis

Linearity Test According to DIN EN ISO 9562 (Column Method) (EN)

Open PDF

TOC Determination in Brine Samples coming from Desalting Process (EN)

Open PDF

TOC-Bestimmung in Sole-Proben aus der Erdöl-Entsalzung (DE)

Open PDF

Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)

Open PDF

Determination of Adsorbable Organic Halogens in Highly Saline Water Samples after Solid Phase Extraction (EN)

Open PDF

TOC Determination in Raw and Drinking Water (EN)

Open PDF

TOC Control in Boiler Feed and Cooling Water of Fossil Fuel Fired and Nuclear Power Plants (EN)

Open PDF

TOC/TNb Determination in Municipal Sewage Plants (EN)

Open PDF

TOC/TNb Determination in Refinery Effluents (EN)

Open PDF

TOC/TNb-Bestimmung in Raffinerieabwässern (DE)

Open PDF

TOC/TNb-Bestimmung in Prozessabwässern der Papier-und Zellstoffindustrie (DE)

Open PDF

TOC/TNb Determination in Pulp and Paper Process Effluents (EN)

Open PDF

Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)

Open PDF

Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)

Open PDF

TOC-Wiederfindung in partikelhaltigen Proben mit dem Cellulose-Test nach DIN EN 1484 (DE)

Open PDF

TOC Recovery in Particle-Containing Samples with the Cellulose Test According to DIN EN 1484 (EN)

Open PDF

Linearity Test According to DIN EN ISO 9562 (Column Method) (EN)

Open PDF

Linearitätstest für die AOX-Bestimmung nach DIN EN ISO 9562 (Säulenmethode) (DE)

Open PDF

TOC/TNb Determination in Municipal Sewage Plants (EN)

Open PDF

TOC/TNb-Bestimmung in kommunalen Kläranlagen (DE)

Open PDF

TOC/TNb Determination in Refinery Effluents (EN)

Open PDF

TOC/TNb-Bestimmung in Raffinerieabwässern (DE)

Open PDF

TOC/TNb-Bestimmung in Prozessabwässern der Papier-und Zellstoffindustrie (DE)

Open PDF

TOC/TNb Determination in Pulp and Paper Process Effluents (EN)

Open PDF

Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)

Open PDF

Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)

Open PDF

TOC-Wiederfindung in partikelhaltigen Proben mit dem Cellulose-Test nach DIN EN 1484 (DE)

Open PDF

TOC Recovery in Particle-Containing Samples with the Cellulose Test According to DIN EN 1484 (EN)

Open PDF

Elemental analysis AAS, ICP-MS, and ICP-OES

The analysis of toxic and ecotoxic elements is an important topic in environmental monitoring. All over the world defined regulations exist for analytical methods for the quantitative detection of lowest element concentrations. Special challenges for environmental monitoring laboratories are high sample throughput and the increasing complexity of the parameters to be monitored, as well as the increasing demands on the detection limits, all this at lowest costs.

Reliable detection of heavy metals in industrial wastewater and sludges

Heavy metals such as lead (Pb), cadmium (Cd) or nickel (Ni) are often released into the environment through industrial effluents and sludges. Some of these metals are toxic and can pollute soils and natural waters ecologically. Control of these effluents and sludges is therefore essential. Here you can find out which reliable analytical methods exist and how you can safely detect heavy metals in industrial wastewater and sludge.

Learn more

Applications elemental analysis

Direct Analysis of Saline Matrices by HR ICP-OES

Open PDF

Determination of Hg in Environmental Waters Using the PlasmaQuant MS Elite (English)

Open PDF

Determination of Toxic and Eco-toxic Elements in Industrial Effluents

Open PDF

Determination of EOF in surface water with molecular absorption spectrometry (EN)

Open PDF

Schnell-sequentielle Analyse giftiger Elemente in Abwasser und Klärschlamm mit der HR-CS AAS

Open PDF

Fast-sequential Analysis of Toxic Elements in Wastewater and Sewage Sludge by HR-CS AAS

Open PDF

UV/Vis spectroscopy Double-beam UV/Vis photometry

Many parameters in wastewater, which have to be monitored regularly, such as ammonia, nitrate, nitrite, phosphate, turbidity, SAC, COD, and BOD can be analyzed with UV/Vis spectrophotometers. Herewith not only qualitative and quantitative analyses of the parameters are possible, but also substance-specific information can be obtained. The measurement results by means of UV/Vis spectrometry are quickly available, reliable, and cost-effective. They are suitable for optimization and control of processes in wastewater treatment plants and for checking the reference and limit values.

Applications UV/vis spectroscopy

Bestimmung der Konzentration mithilfe einer Kalibrierkurve – am Beispiel von Tensid- Messungen nach PD CLC/TS 50677:2019

Open PDF

Spektrophotometrische Bestimmung von Standardparametern in Abwasser nach Normverfahren

Open PDF

Spectrophotometric Determination of Standard Parameters in Wastewater According to Standard Methods

Open PDF

Determination of Concentration by Means of a Calibration Curve – Exemplified by Surfactant Measurements According to PD CLC/TS 50677:2019

Open PDF

Analysis of Solid Matrices

Learn more

Air Pollution Control

Learn more

Water Analysis

Learn more

Contact